Skip to main content
Schneider Electric A9F05250 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F05250 Acti9 iC60N MCB, D Curve 50 A 2P

MPNA9F05250
Obsolete

Schneider Electric Acti9 iC60N, A9F05250, miniature circuit-breaker, D curve, 50 A rated current, 2 poles, 36 kA breaking capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F05250 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameIC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F05250 — Electrical
ParameterValue
Rated current [In]50 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F05250 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F05250 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F05250 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F05250 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05250 is an Acti9 iC60N miniature circuit-breaker (MCB) rated 50 A with a D tripping curve, 2 poles, and a 36 kA ultimate breaking capacity (Icu) at 12–133 V AC. It's certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/light commercial), so it qualifies for isolation duty per both standards.

Deployment and integration

Snaps onto a DIN rail — 36 mm wide, 4 x 9 mm pitches, 91 mm tall, 78.5 mm deep. The double terminals on top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible, with a 14 mm strip length and 3.5 N·m tightening torque. Overvoltage category IV suits it for the main distribution board, not just sub-panels.

Frequently asked questions

Where can I buy the A9F05250 and get a price?

The A9F05250 is sourced and quoted to order against an RFQ through our independent distribution channel. Submit an RFQ for current availability and pricing — confirmed at quote time, no stock or price figures published here.

What does the D curve mean on this MCB?

The D curve sets the magnetic trip threshold at 12 x In ±20% — for a 50 A breaker, that's roughly 480–720 A instantaneous trip. It's designed for loads with high inrush like motors, transformers, and welding equipment, where a B or C curve would nuisance-trip on startup.

What breaking capacity does the A9F05250 have at 400 V?

At 380–415 V AC the Icu is 10 kA per EN/IEC 60947-2; the Icn at 400 V per EN/IEC 60898-1 is 6 kA. The higher 36 kA rating applies at 12–133 V AC.

What compliance documentation is available for the A9F05250?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1. It carries IP20 protection and is suitable for isolation duty under both standards. Specific RoHS/REACH/UL declarations should be requested at quote time.

MPN