Schneider Electric A9F05316 Acti9 iC60N MCB, D Curve 16 A 3P

MPNA9F05316
Active

Schneider Electric Acti9 iC60N, A9F05316, miniature circuit breaker, 3P, 16 A, D curve, 36 kA breaking capacity, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F05316 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F05316 — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F05316 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F05316 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F05316 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F05316 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05316 is an Acti9 iC60N miniature circuit breaker — 3 poles, 16 A rated current, D curve. The D curve magnetic trip fires at 12 x In (±20 %), so it tolerates the inrush of motor and transformer loads without nuisance tripping while still clearing a hard fault. 36 kA Icu at 12–133 V AC and 20 kA at 220–240 V AC means it can interrupt high fault currents on the secondary side of a distribution transformer; at 400 V the Icu drops to 10 kA, and the Icn per EN/IEC 60898-1 is 6 kA at 400 V — the lower figure governs for residential or light commercial final circuits. Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic), so it fits either a panelboard or an industrial load center.

Snaps onto a DIN rail — 6 x 9 mm pitch modules wide (54 mm). Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; torque to 2 N·m. IP20 finger-safe front, so it can live in an open panel without shrouds. Trip indicator and contact position indicator give a visual on state without needing to measure downstream voltage. Earth-leakage protection is handled by a separate block (not integral).

Current production — no phase-out or NRND flag on record.

Frequently asked questions

What is A9F05316's breaking capacity at 400 V?

At 400 V AC, the Icu per EN/IEC 60947-2 is 10 kA, and the Icn per EN/IEC 60898-1 is 6 kA. The 6 kA figure is the one that governs for residential-type final circuits under the domestic standard.