Skip to main content
Schneider Electric A9F05463

A9F05463 Acti9 iC60N D Curve 63A 4P MCB, 36 kA Breaking

MPN A9F05463
Active

Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F05463, 4P, 63 A, D curve, thermal-magnetic trip, 36 kA Icu at 12–133 V AC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05463 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F05463 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F05463 is a 4-pole 63 A miniature circuit-breaker from the Acti9 iC60N family, built around a thermal-magnetic trip unit with a D curve. The 36 kA Icu at 12–133 V AC (EN/IEC 60947-2) is the maximum fault current it can safely interrupt; at 220–240 V AC that drops to 20 kA, and at 380–415 V AC to 10 kA. For a 400 V distribution board, the 10 kA Icu (and 6 kA Icn per EN/IEC 60898-1) tells you the fault level the board must stay under for this breaker to clear without welding its contacts. The 4 protected poles give full isolation on all phase conductors, and the suitability-for-isolation marking (per both EN/IEC 60898-1 and 60947-2) means you can lock it off for safe maintenance downstream.

The double terminals accept 1–35 mm² rigid or 1–25 mm² flexible on top or bottom, with a tightening torque of 3.5 N·m. Strip length is 14 mm. IP20 rated, so it lives inside an enclosed panel, not on the wet side of the gland plate.

MPN
A9F05463