Specifications

A9F05470 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F05470 — Ratings
ParameterValue
Rated current (In)0.5 A
Poles configuration4P
Number of protected poles4
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F05470 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F05470 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F05470 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F05470 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F05470 is an Acti9 iC60 miniature circuit-breaker (MCB) rated 0.5 A with a D tripping curve, 4 poles, and a 50 kA breaking capacity at 415 V AC. At 0.5 A it's a low-current branch feeder, not a main; think control transformer secondary or a small pump motor.

Mounting and integration — DIN rail, 4-pole, 8 modules wide

Snaps onto standard DIN rail per. At 72 mm wide (8 x 9 mm pitches), it occupies eight module spaces in the enclosure — plan your rail layout accordingly. IP20 rated — fine for enclosed panels, not for washdown zones.

Standards and compliance — dual-rated to EN/IEC 60898-1 and 60947-2

Dual-certified to both EN/IEC 60898-1 (the household / similar installation standard) and EN/IEC 60947-2 (the industrial standard for low-voltage switchgear). That means it's accepted in residential, commercial, and industrial distribution boards — the 60947-2 rating gives you the higher Icu breaking capacities (50 kA at 415 V) and the pollution degree 3 rating for harsher environments. Overvoltage category IV suits it for the main distribution point.

Frequently asked questions

Where can I buy A9F05470 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is A9F05470's listed depth?

The depth is 78.5 mm.

What is A9F05470's range?

It belongs to the Acti9 range, specifically the Acti9 iC60 product family.

What compliance documentation does this brand provide for A9F05470?

The MCB is certified to EN/IEC 60898-1 and EN/IEC 60947-2, with tropicalisation class 2 per IEC 60068-1 and pollution degree 3 per EN/IEC 60947-2. It is suitable for isolation per both standards.

MPN