Skip to main content
Schneider Electric A9F06163

Schneider Electric A9F06163 Acti9 iC60H MCB, 63 A, 1P, B Cur

MPN A9F06163
Obsolete

Schneider Electric Acti9 iC60H, A9F06163, 1-pole miniature circuit breaker, 63 A rated, B-curve, thermal-magnetic trip, DIN rail mount, 42 kA breaking capacity at 12-60 VAC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06163 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06163 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

What the 63 A B-curve rating means for your panel

The A9F06163 is a 1-pole Acti9 iC60H miniature circuit breaker rated 63 A with a B-curve trip characteristic — magnetic tripping at 4 x In (±20 %), so it clears short-circuits between 252 A and 302 A. The thermal-magnetic trip unit handles the overload side; the magnetic element handles the short-circuit side. It's dual-rated to EN/IEC 60947-2 (utilisation category A) and EN/IEC 60898-1, so it can serve either distribution board or industrial panel duty — the 60947-2 rating gives you the higher breaking capacities for industrial coordination studies.

Breaking capacity — the number that governs fault coordination

The iC60H frame carries a 42 kA Icu at 12-60 VAC, 30 kA at 100-133 VAC, and 15 kA at 220-240 VAC (per EN/IEC 60947-2). On DC: 20 kA at 12-60 VDC, 15 kA at 60-72 VDC. Under the 60898-1 standard for household-type installations, it's rated 10,000 A Icn at 230 VAC. That's a high-interrupting-capacity (H) frame — useful if you're coordinating downstream of a transformer or in a high-fault location.

Mounting and integration — drops into a standard DIN rail slot

Snap-on DIN rail mount, 18 mm width (2 x 9 mm pitches), 91 mm height, 78.5 mm depth. That's a standard 1-pole modular width — it occupies one slot in any Acti9 or third-party distribution board. The double terminals accept 1-35 mm² rigid or 1-25 mm² flexible on top or bottom. Wire strip length 14 mm. IP20 finger-safe protection. The white housing with toggle and trip indicator gives local status at a glance.

MPN
A9F06163