Skip to main content
Schneider Electric A9F06240

Schneider Electric A9F06240 Acti9 iC60H MCB, 40 A, 2P, B-Cur

MPN A9F06240
Active

Schneider Electric Acti9 iC60H, A9F06240, 40 A, 2-pole, B-curve miniature circuit breaker, 42 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06240 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06240 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F06240 is a 40 A, 2-pole miniature circuit breaker from the Acti9 iC60H range, with a B-curve trip characteristic. The B-curve means the magnetic trip fires at 4 x In (±20%) — so for this 40 A breaker, instantaneous trip occurs between roughly 128 A and 192 A. That's a good fit for resistive or general-purpose loads where you don't want nuisance trips from moderate inrush.

Breaking capacity and where it matters

This breaker's interrupting capacity is 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC (per EN/IEC 60947-2). Under the 60898-1 standard it's rated 15 kA Icn at 400 V. That's a high-fault-rated device — it can handle the fault currents you'd see close to a transformer or in a heavy industrial panel, not just a light commercial sub-board. The 2-pole version protects both phase and neutral on a single-phase circuit, or two poles of a three-phase system.

Snaps onto a DIN rail — 36 mm wide (4 x 9 mm pitches), 91 mm tall, 78.5 mm deep. That's a standard 2-module width for a 2-pole MCB in the Acti9 family, so it fits existing DIN-rail enclosures and distribution boards without surprises. The double-terminal design (top and bottom) lets you daisy-chain outgoing circuits without piggybacking on the busbar.

MPN
A9F06240