Schneider Electric A9F06250 — 2-Pole MCB (DIN Rail)

A9F06250 Acti9 iC60H MCB, 50 A, 2P, Curve B, 42 kA Icu

MPNA9F06250
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F06250, 50 A, 2-pole, curve B, 42 kA Icu at 12-133 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06250 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution

Electrical

A9F06250 — Electrical
ParameterValue
Rated current [In]50 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz

Protection

A9F06250 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06250 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes

Environmental

A9F06250 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C

Approvals

A9F06250 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06250 is a Schneider Electric Acti9 iC60H miniature circuit breaker — 50 A rated current, 2-pole, curve B, with a 42 kA Icu breaking capacity at 12-133 V AC.

At 220-240 V AC it still holds 30 kA Icu, and at 380-415 V AC it's 15 kA Icu. The curve B magnetic trip (4 x In ±20%) means it trips instantaneously at 200 A (4 × 50 A) — that's a fast, low-threshold trip designed for resistive loads like heaters, lighting banks, and control transformers where inrush is minimal. For motor or drive circuits with higher inrush, a curve C or D would be the better call; this one stays in the distribution and general-purpose zone.

The IP20 finger-safe front allows panel-door mounting without additional shrouding. Pollution degree 3 rating means it's suitable for industrial enclosures where conductive dust or humidity is present — no derating needed for typical control-panel environments.

Dual-certified to EN/IEC 60947-2 (industrial circuit-breaker standard) and EN/IEC 60898-1 (household/miniature breaker standard) — so it qualifies for both industrial panelboards and commercial distribution boards. Isolation suitability is confirmed under both standards. The thermal-magnetic trip unit provides overload protection via the thermal bimetal and short-circuit protection via the solenoid.

Frequently asked questions

What is A9F06250's breaking capacity at 400 V?

At 400 V AC, the A9F06250 has a 15 kA Icu per EN/IEC 60947-2 and a 10 kA Icn per EN/IEC 60898-1. The higher 42 kA rating applies at 12-133 V AC.

What is the closest alternative to A9F06250 in the Acti9 range?

Within the Acti9 iC60 range, the A9F06250 is the 50 A, 2-pole, curve B, high-performance (H) variant. The standard-performance 'N' variant (iC60N) has a lower breaking capacity — typically 6-10 kA Icn — while the 'L' variant (iC60L) offers 15 kA Icn at 400 V. For the same 50 A, 2P, curve B configuration, the iC60N order code would be A9F05250 and the iC60L would be A9F07250. The H variant here splits the difference with 10 kA Icn at 400 V.

Where can I buy A9F06250?

The A9F06250 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
A9F06250