Skip to main content
Schneider Electric A9F06313

Schneider Electric A9F06313 Acti9 iC60H MCB, 3P, 13 A, Curve

MPN A9F06313
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 3P, 13 A, curve B, breaking capacity 42 kA Icu at 133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06313 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06313 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F06313 is an Acti9 iC60H miniature circuit-breaker, 3-pole, rated 13 A with a B-curve trip characteristic. It is designed for distribution boards and sub-distribution panels where the load is primarily resistive or low-inrush, such as lighting circuits or small control transformers.

Breaking capacity is the headline here: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V, all per EN/IEC 60947-2. That iC60H suffix signals the high-breaking variant — the standard iC60 (no H) tops out at 25 kA at 220–240 V. If your panel's prospective short-circuit current at the busbar exceeds 25 kA, this H version is the one that holds without upstream fuses. The 10 kA Icn at 400 V per EN/IEC 60898-1 covers the domestic/commercial certification path.

The 78.5 mm depth leaves clearance for a standard enclosure door with the toggle and trip indicator visible. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible, with a 2 N·m tightening torque.

The thermal-magnetic trip unit gives a fixed thermal curve with magnetic pickup at 4 x In ±20 %. Electrical durability is 10,000 cycles, mechanical 20,000 — figure on replacing it after roughly 10 years of daily switching in a lighting panel. IP20 finger-safe terminals; separate earth-leakage block (Vigi iC60) can be added on the downstream side without extra DIN width.

MPN
A9F06313