Skip to main content
Schneider Electric A9F06313 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F06313 Acti9 iC60H MCB, 3P, 13 A, Curve

MPNA9F06313
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 3P, 13 A, curve B, breaking capacity 42 kA Icu at 133 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06313 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06313 — Ratings
ParameterValue
Rated current (In)13 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06313 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06313 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F06313 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06313 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F06313 is an Acti9 iC60H miniature circuit-breaker, 3-pole, rated 13 A with a B-curve trip characteristic. It is designed for distribution boards and sub-distribution panels where the load is primarily resistive or low-inrush, such as lighting circuits or small control transformers.

Breaking capacity is the headline here: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V, all per EN/IEC 60947-2. That iC60H suffix signals the high-breaking variant — the standard iC60 (no H) tops out at 25 kA at 220–240 V. If your panel's prospective short-circuit current at the busbar exceeds 25 kA, this H version is the one that holds without upstream fuses. The 10 kA Icn at 400 V per EN/IEC 60898-1 covers the domestic/commercial certification path.

The 78.5 mm depth leaves clearance for a standard enclosure door with the toggle and trip indicator visible. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible, with a 2 N·m tightening torque.

The thermal-magnetic trip unit gives a fixed thermal curve with magnetic pickup at 4 x In ±20 %. Electrical durability is 10,000 cycles, mechanical 20,000 — figure on replacing it after roughly 10 years of daily switching in a lighting panel. IP20 finger-safe terminals; separate earth-leakage block (Vigi iC60) can be added on the downstream side without extra DIN width.

Frequently asked questions

What is the breaking capacity of A9F06313?

The breaking capacity varies by voltage: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V, all per EN/IEC 60947-2. It also carries a 10 kA Icn at 400 V per EN/IEC 60898-1.

What is the closest alternative to A9F06313 in the same family?

The standard-breaking iC60N (e.g., A9F06303) is the closest pin-compatible alternative, but its breaking capacity tops out at 25 kA at 220–240 V. If your panel's prospective fault current is below that, the iC60N saves cost; above it, the iC60H (A9F06313) is the correct choice.

Where can I buy A9F06313?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What compliance documentation does Schneider provide for A9F06313?

The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries a suitability-for-isolation marking per both standards. The Acti9 range typically includes CE, UKCA, and EAC declarations; specific RoHS/REACH declarations are available from Schneider's documentation portal.

MPN
A9F06313