Schneider Electric Acti9 iC60H, A9F06332, 3P miniature circuit breaker, 32 A, B curve, 42 kA Icu at 12–133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06332 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06332 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06332 is a Schneider Electric Acti9 iC60H miniature circuit breaker — 32 A rated current, 3-pole, B-curve trip characteristic. The 42 kA Icu at 12–133 V AC is the maximum short-circuit current it can interrupt without damage at those voltages; at 400 V AC the Icn is 15 kA per EN/IEC 60898-1, which is the standard domestic/commercial breaking capacity. That 15 kA at 400 V tells you it's rated for distribution boards with moderate fault levels — not for high-fault industrial mains. The thermal-magnetic trip unit covers both overload (thermal bimetal) and short-circuit (magnetic coil). It's certified to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household), so it can be specified in either context. The 3-pole configuration (3P) switches all three phases simultaneously, which is standard for three-phase distribution. DIN-rail mounting (snap-on) means it clips directly onto the standard 35 mm rail in any distribution board or sub-panel.