Skip to main content
Schneider Electric A9F06416 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F06416 Acti9 iC60H MCB, 16A Curve B 4P

MPNA9F06416
Active

Schneider Electric Acti9 iC60H, A9F06416, miniature circuit breaker, 4P, 16 A rated, B-curve, 42 kA breaking capacity at 133 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06416 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06416 — Ratings
ParameterValue
Rated current (In)16 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06416 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06416 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F06416 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06416 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F06416 is an Acti9 iC60H miniature circuit breaker — 4 poles, 16 A rated current, B-curve trip characteristic. Breaking capacity hits 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V — that's a high-interrupting frame for a 16 A MCB, meaning it can ride through a stiff fault on a large transformer without welding its contacts shut. The 10 kA Icn at 400 V per EN/IEC 60898-1 covers the standard domestic/commercial panel fault level. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar), which gives it a foot in both worlds: the 60947-2 listing carries the higher Icu ratings and isolation suitability, while the 60898-1 listing gives the standard Icn for branch-circuit protection.

IP20 finger-safe front, so it's panel-mount only — no washdown rating.

Carries the usual Schneider declaration of performance and CE marking per the Low Voltage Directive.

Frequently asked questions

What is the breaking capacity of the A9F06416 at 400 V?

At 400 V AC, the A9F06416 carries a 15 kA Icu per EN/IEC 60947-2 and a 10 kA Icn per EN/IEC 60898-1.

What is the closest alternative to the A9F06416 in the Acti9 family?

The standard iC60 (without the H suffix) is the same physical footprint and rating but with lower breaking capacity — typically 6 kA or 10 kA Icn instead of the 10–42 kA range on the iC60H. If your panel fault current is under 10 kA, the standard iC60 saves cost; if you need the higher interrupt rating, stick with the A9F06416.

Where can I buy the A9F06416?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9F06416