Schneider Electric A9F06420 Acti9 iC60H MCB, 20 A, 4P, B Cur

MPNA9F06420
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 4P, 20 A, B curve, 42 kA Icu at 12-133 V AC, thermal-magnetic trip, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06420 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06420 — Ratings
ParameterValue
Rated current (In)20 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06420 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06420 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F06420 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06420 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F06420 is an Acti9 iC60H miniature circuit breaker (MCB) rated for 20 A with a B curve, 4 poles, and a thermal-magnetic trip unit. It's built for distribution panels and protects branch circuits against overloads and short circuits, with a 42 kA Icu breaking capacity at 12-133 V AC and 30 kA at 220-240 V AC per EN/IEC 60947-2.

It's rated for isolation per both standards, carries overvoltage category IV, and pollution degree 3 — so it's designed for the harsh electrical environment of a main distribution board.

Terminals accept double conductors: 1-25 mm² rigid or 1-16 mm² flexible, with a 14 mm strip length and 2 N.m torque. IP20 finger-safe terminals are standard for enclosed panels. The white housing with toggle and trip indicator gives clear visual status on the rail.

The A9F06420 is a current-production Acti9 iC60H MCB.

Frequently asked questions

Where can I buy the A9F06420 and get a price?

The A9F06420 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability — no stock or price figures are published here.

What is the breaking capacity of the A9F06420 at 400 V?

At 380-415 V AC, the Icu is 15 kA per EN/IEC 60947-2. At 400 V AC, the Icn per EN/IEC 60898-1 is 10 kA (15 kA Icu at 380-415 V).

What compliance documentation does Schneider provide for the A9F06420?

The A9F06420 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries tropicalisation class 2 per IEC 60068-1 and is rated for isolation per both standards. RoHS, REACH, and UL documentation should be available from Schneider Electric's documentation portal — the evidence here confirms the IEC standards but does not list specific RoHS/REACH/UL certificates.

MPN
A9F06420