Skip to main content
Schneider Electric A9F06425

Schneider Electric A9F06425 Acti9 iC60H MCB, 25 A, 4P, B-Cur

MPN A9F06425
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 4P, 25 A, B-curve, 42 kA Icu at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06425 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06425 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F06425 is an Acti9 iC60H miniature circuit-breaker (MCB) rated for 25 A with a B-curve trip characteristic, 4 poles, and a 42 kA Icu breaking capacity at 12-133 V AC.

The 60947-2 rating (42 kA Icu at 12-133 V AC, 30 kA at 220-240 V, 15 kA at 380-415 V, 10 kA at 440 V) is the industrial breaking capacity — it tells you the MCB can safely interrupt a fault up to those levels without welding its contacts or exploding. The 60898-1 rating (15 kA Icn at 400 V) is the domestic/commercial rating. The overvoltage category IV and pollution degree 3 ratings mean this MCB is rated for main incoming supply panels, not just sub-distribution.

The 4-pole body occupies 8 x 9 mm pitches — 72 mm wide total. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible wire; double terminals on top and bottom allow daisy-chaining without extra distribution blocks. IP20 finger-safe protection means it is for use inside an enclosure, not exposed. The toggle actuator and trip indicator give clear visual status for commissioning and maintenance.

Environmental and durability

Rated for 10,000 electrical cycles and 20,000 mechanical cycles — sufficient for most distribution panels where the MCB is operated infrequently (isolation switching).