Skip to main content
Schneider Electric A9F06616 — 1-Pole MCB (DIN Rail)

Schneider Electric A9F06616 Acti9 iC60H MCB, 16 A, 1P+N, Cur

MPNA9F06616
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F06616, 16 A rated current, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC, DIN rail mount, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06616 — Identification
ParameterValue
Product nameActi9 iC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiC60H
Poles description1P + N
Number of protected poles1
Device applicationDistribution

Electrical & Protection

A9F06616 — Electrical & Protection
ParameterValue
Rated current (In)16 A
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu / AIR)42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles

Mounting & Connection

A9F06616 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Width36 mm
Height91 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m top or bottom

Environmental

A9F06616 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529

Approvals

A9F06616 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1

Electrical

A9F06616 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

The Schneider Electric A9F06616 is a miniature circuit breaker from the Acti9 iC60H series, rated 16 A, 1P+N, with a B tripping curve. It is a thermal-magnetic MCB designed for distribution in final subcircuits. The B curve means magnetic tripping occurs between 3.2 and 4.8 times rated current (4 x In +/- 20 %) — suited for resistive or general-purpose loads where inrush is low. It carries a 42 kA breaking capacity at 12-60 V AC, which is the Icu per IEC 60947-2; the Icn per IEC 60898-1 is 10 kA at 230 V AC. That dual rating tells you this breaker is certified to both standards — it can be specified in industrial panels (60947-2) or residential/commercial distribution boards (60898-1). The 1P+N configuration switches the phase and provides a switched neutral on the left side.

Mounts on DIN rail, occupies 4 x 9 mm pitches — that is 36 mm width, 91 mm height, 78.5 mm depth. IP20 finger-safe terminals — fine for enclosed panels; not for washdown zones. Overvoltage category IV — rated for the main distribution board, not just sub-distribution.

Suitability for isolation is confirmed under both standards. Separate earth-leakage protection block can be added. Contact position indicator and trip indicator give clear visual status.

Frequently asked questions

How do I get current pricing and availability for A9F06616?

Submit an RFQ for the A9F06616. We source it to order through independent distribution; availability and current pricing are confirmed at quote time. No stock count or lead-time number is published here.

What is A9F06616's breaking capacity?

The A9F06616 has a 42 kA Icu at 12-60 V AC per IEC 60947-2, and a 10 kA Icn at 230 V AC per IEC 60898-1.

What is the closest alternative to A9F06616 in the same family?

Within the Acti9 iC60 range, the main variant is the curve choice: the A9F06616 is curve B. For the same 16 A, 1P+N rating, a curve C version (e.g., A9F07616) would trip magnetically at 5-10 x In instead of 3.2-4.8 x In — use curve C for moderate inrush loads like small motors or transformers. The footprint and breaking capacity are identical.

MPN
A9F06616