Skip to main content
Schneider Electric A9F07150

Schneider Electric A9F07150 Acti9 iC60H MCB, 50 A, 1P, C Cur

MPN A9F07150
Active

Schneider Electric Acti9 iC60H, A9F07150, miniature circuit-breaker, 1P, 50 A, C curve, 42 kA Icu, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07150 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07150 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Schneider Electric A9F07150 is an Acti9 iC60H miniature circuit-breaker, 1-pole, rated 50 A with a C curve. That 18 mm width means it slots into a crowded panel without eating up rail space — one less thing to re-layout.

The iC60H carries a 42 kA Icu at 12…60 V AC and 30 kA Icu at 100…133 V AC, dropping to 15 kA Icu at 220…240 V AC. For a 50 A MCB on a 230/240 V distribution board, 15 kA Icu gives you headroom above typical domestic and light commercial prospective fault levels. The C curve (magnetic trip at 8 x In ±20 %) means it holds through motor inrush and transformer energization but trips fast on a hard short — a good fit for general distribution and mixed loads.

Snaps onto a DIN rail (mounting support: DIN rail).

MPN
A9F07150