Skip to main content
Schneider Electric A9F07213 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F07213 Acti9 iC60H MCB, 13 A, 2P, C-Cur

MPNA9F07213
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F07213, 13 A, 2P, C-curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07213 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution

Electrical

A9F07213 — Electrical
ParameterValue
Rated current [In]13 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz

Protection

A9F07213 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07213 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes

Environmental

A9F07213 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C

Approvals

A9F07213 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

13 A, 2-pole C-curve MCB for distribution boards

The Schneider Electric A9F07213 is an Acti9 iC60H miniature circuit breaker rated at 13 A with a C-curve trip characteristic, covering 2 protected poles in a 36 mm wide DIN-rail housing. The thermal-magnetic trip unit gives you both overload protection (bimetal strip) and short-circuit protection (solenoid) in one package. Breaking capacity is the headline here: 42 kA Icu at 12-133 V AC, 30 kA at 220-240 V AC, 15 kA at 380-415 V AC, and 10 kA at 440 V AC per EN/IEC 60947-2. That puts it in the high-breaking-capacity class (iC60H) — suitable for installation close to the transformer or in high-fault-current panels where standard 6 kA or 10 kA MCBs would need upstream fusing or a current-limiting breaker. The 15 kA Icn at 400 V per EN/IEC 60898-1 confirms it meets the domestic/commercial standard as well.

Dual standard certification and isolation suitability

This breaker carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), which means it can be specified for either a panelboard in a factory or a distribution board in a building without swapping part numbers. The IP20 finger-safe front keeps live terminals out of reach on the panel face.

The toggle control gives a clear visual indication of the contact position, and the trip indicator shows when the breaker has tripped on fault — useful for troubleshooting without removing the panel cover.

Frequently asked questions

What is the breaking capacity of the A9F07213 at 400 V?

At 380-415 V AC the breaking capacity is 15 kA Icu per EN/IEC 60947-2, and at 400 V it is rated 15 kA Icn per EN/IEC 60898-1.

What is the closest alternative to the A9F07213 in the Acti9 range?

Within the Acti9 iC60H family, the closest peer is the same 2-pole C-curve breaker at a different current rating — the A9F07213 is the 13 A variant. No pin-compatible direct substitute exists at a different current; select the rating that matches the load.

Where can I buy the A9F07213?

The A9F07213 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for the A9F07213?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries an IP20 rating per IEC 60529 and tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range.

MPN