Schneider Electric A9F07240 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F07240 Acti9 iC60H MCB, 40 A, 2P, C-Cur

MPNA9F07240
Obsolete

Schneider Electric Acti9 iC60H, A9F07240, miniature circuit breaker, 2P, 40 A, C-curve, 42 kA Icu at 12–133 V AC, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F07240 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F07240 — Electrical
ParameterValue
Rated current [In]40 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F07240 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F07240 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F07240 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F07240 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F07240 is a Schneider Electric Acti9 iC60H miniature circuit breaker — 2 poles, 40 A rated current, C-curve magnetic trip (8 x In ±20 %). The C-curve means it holds through moderate inrush (motor starts, capacitor banks) and trips fast on hard shorts; the 40 A continuous rating governs the downstream conductor sizing. Breaking capacity hits 42 kA Icu at 12–133 V AC and 30 kA at 220–240 V AC, both per EN/IEC 60947-2 — that is utility-grade fault clearing, not just branch-panel level. At 400 V AC it still holds 15 kA Icu, so it coordinates with upstream switchgear in a typical 400 V distribution board. It is certified to both EN/IEC 60898-1 (household MCB standard) and EN/IEC 60947-2 (industrial circuit-breaker standard), which means it qualifies for either residential final circuits or industrial panel feeders — the dual rating is rare in a 2-module-wide package.

IP20 finger-safe protection on the front face. The toggle actuator gives a clear visual trip indication (red/green flag) and a contact-position indicator for safe isolation verification — both required by EN/IEC 60947-2 for an isolating device.

The Acti9 iC60H series is the high-breaking-capacity variant of the iC60 family (iC60N is the standard 6–10 kA version; iC60H hits 15–42 kA depending on voltage). If your panel SCCR study demands the higher fault rating, this is the one. No pin-compatible alternative exists within the same footprint — the iC60N shares the same housing and terminals but lower kA, so a substitution would require a coordination re-check.

The thermal-magnetic trip unit is sealed against corrosion.

Frequently asked questions

Where can I buy A9F07240 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to A9F07240 in the Acti9 family?

The Acti9 iC60N (standard breaking capacity) shares the same housing, terminals, and 40 A C-curve rating, but its breaking capacity is lower (typically 6–10 kA). Swapping to the iC60N requires a coordination study to verify the available fault current at the installation point.

What is A9F07240's depth?

78.5 mm deep, 91 mm tall, 36 mm wide (4 x 9 mm pitches). Fits standard 35 mm DIN rail enclosures.

What compliance documentation does Schneider provide for A9F07240?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. Pollution degree 3, overvoltage category IV. Suitable for isolation per both standards.