Skip to main content
Schneider Electric A9F07270 — 2-Pole MCB (DIN Rail)

Schneider A9F07270 Acti9 iC60H MCB, 0.5 A, C Curve, 2P, 70 k

MPNA9F07270
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F07270, 0.5 A rated current, C curve, 2 poles, 70 kA Icu at 240 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07270 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution

Electrical

A9F07270 — Electrical
ParameterValue
Rated current [In]0.5 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC
Network frequency50/60 Hz

Protection

A9F07270 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07270 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes

Environmental

A9F07270 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C

Approvals

A9F07270 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

Schneider Electric A9F07270 is an Acti9 iC60H miniature circuit breaker rated at 0.5 A, C curve, 2 poles, with 70 kA Icu at 220...240 V AC.

At 380-415 V it holds 70 kA, at 440 V it derates to 50 kA. IEC 60898-1 rating gives 15 kA Icn at 400 V. C curve magnetic trip at 8 x In (±20%) means it trips instantaneously between 3.2 and 4.8 A — suited for resistive and general loads, not high-inrush motor circuits. Utilisation category A (EN/IEC 60947-2) confirms it's not intended for motor starting duty under short-circuit conditions.

Panel integration and termination

Mounts on DIN rail, 36 mm width (4 x 9 mm pitches), 91 mm height, 78.5 mm depth. Tightening torque 2 N.m, strip length 14 mm. IP20 finger-safe front, pollution degree 3, overvoltage category IV — suitable for main distribution boards, not wet environments. Earth-leakage protection requires a separate Vigi iC60 block (not included) — the MCB itself provides overcurrent and short-circuit only. Trip indicator and contact position indicator give visual confirmation of state without opening the door.

Suitability for isolation marked yes to both standards — it can be used as a disconnecting means with visible gap confirmation.

Frequently asked questions

What is A9F07270's breaking capacity at 240 V?

70 kA Icu at 220...240 V AC (EN/IEC 60947-2) and 15 kA Icn at 400 V (EN/IEC 60898-1). At 440 V it holds 50 kA Icu.

MPN
A9F07270