Schneider Electric A9F07304 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F07304 Acti9 iC60H MCB, 4 A, C Curve, 3

MPNA9F07304
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 3P, 4 A, C curve, 70 kA Icu at 415 V AC, DIN rail mount, white.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07304 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F07304 — Ratings
ParameterValue
Rated current (In)4 A
Poles configuration3P
Number of protected poles3
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F07304 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07304 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F07304 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F07304 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F07304 is a 3-pole miniature circuit breaker from the Acti9 iC60H series, rated 4 A with a C-curve trip characteristic (magnetic trip at 8 x In ±20%). That C curve means it's sized for general-purpose distribution loads — lighting, small transformers, control circuits — where inrush isn't extreme but you still want fast clearing on a hard short. The thermal-magnetic trip gives you both overload protection (thermal bimetal) and short-circuit protection (solenoid).

Deployment context — DIN-rail panel integration

Snaps onto standard DIN rail (35 mm) — the 9 mm pitch count of 6 means it occupies 6 modules (54 mm wide). The toggle control and trip indicator give local status at a glance. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible, with a stripping length of 14 mm and tightening torque of 2 N·m. The IP20 finger-safe enclosure is fine for enclosed panels; not rated for washdown environments.

Standards and approvals — what they certify

Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — so it's accepted in both commercial and light-industrial distribution boards.

Frequently asked questions

Who supplies A9F07304 and how is it quoted for volume purchases?

The part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is A9F07304's breaking capacity at 415 V AC?

70 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V AC per EN/IEC 60898-1.

What does the C curve mean on this MCB?

The C curve trips magnetically at 8 x In ±20% (32 A for this 4 A breaker). It's designed for general-purpose distribution loads with moderate inrush — lighting, control transformers, small motors — not for high-inrush loads like large transformers or motor starters (those need a D curve).

What compliance documentation does Schneider provide for A9F07304?

The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1, with suitability for isolation confirmed under both standards. Tropicalisation class 2 per IEC 60068-1 is also documented.