Skip to main content
Schneider Electric A9F07332 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F07332 Acti9 iC60H MCB, 32 A, 3P, C-Cur

MPNA9F07332
Active

Schneider Electric Acti9 iC60H, A9F07332, miniature circuit breaker, 32 A, 3P, C-curve, breaking capacity 42 kA Icu at 12-133 V AC, 30 kA at 220-240 V AC, 15 kA at 380-415 V AC, 10 kA at 440 V AC, DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07332 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F07332 — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F07332 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07332 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F07332 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F07332 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F07332 is a 32 A, 3-pole miniature circuit breaker from the Acti9 iC60H series, thermal-magnetic trip, C-curve (magnetic trip at 8 x In ±20 %). Rated breaking capacity hits 42 kA Icu at 12-133 V AC and 30 kA at 220-240 V AC (EN/IEC 60947-2); at 400 V the Icn is 10 kA (EN/IEC 60898-1). Mounts on DIN rail (54 mm width, 6 x 9 mm pitches), IP20 finger-safe terminals. Double terminals accept 1-35 mm² rigid or 1-25 mm² flexible — enough for 32 A feeder circuits with standard panel wiring.

Frequently asked questions

How do I get current pricing and availability for A9F07332?

Sourced to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is A9F07332's listed depth?

Depth is 78.5 mm.

What range does A9F07332 belong to?

The Acti9 range — specifically the iC60H device short name.

What compliance documentation does this brand provide for A9F07332?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Pollution degree 3 per 60947-2; tropicalisation class 2 per IEC 60068-1. Separate earth-leakage protection block available.

MPN
A9F07332