Skip to main content
Schneider Electric A9F07363 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F07363 Acti9 iC60H MCB, 63 A, 3P, C-Cur

MPNA9F07363
Active

Schneider Electric Acti9 iC60H, A9F07363, miniature circuit breaker, 3-pole, 63 A, C-curve, 15 kA Icn at 400 V AC, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07363 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F07363 — Ratings
ParameterValue
Rated current (In)63 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F07363 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07363 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F07363 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F07363 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F07363 is an Acti9 iC60H miniature circuit breaker rated at 63 A with a C-curve trip characteristic and 3 protected poles.

Breaking capacity — what 15 kA at 400 V means for selectivity

This breaker carries a 15 kA Icu at 380...415 V AC and a 10 kA Icu at 440 V AC per EN/IEC 60947-2, plus a 10 kA Icn at 400 V AC per EN/IEC 60898-1. The dual certification (60947-2 for industrial and 60898-1 for household/commercial) gives flexibility to use it in either context, though the 60898-1 rating is the lower of the two at 10 kA.

DIN rail integration and wiring

IP20 finger-safe terminals are standard for enclosed panels; no washdown rating here, so keep it behind a gland plate. The toggle actuator and trip indicator give local visual status without opening the panel door.

Overvoltage category IV means it's rated for installation at the origin of the installation (utility side of the main panel).

Frequently asked questions

How do I get current pricing and availability for A9F07363?

Submit an RFQ through this listing. The part is sourced through independent distribution channels; availability and current pricing are confirmed at quote time.

What is the closest alternative to A9F07363 in the Acti9 family?

Within the Acti9 iC60 range, the key variant difference is the curve code (B, C, or D) and the breaking capacity class (iC60N vs iC60H vs iC60L). The A9F07363 is the iC60H, 63 A, C-curve, 3-pole variant. A B-curve version (same rating and poles) would trip faster on inrush and is better for resistive loads; a D-curve version would tolerate higher inrush for heavy motor or transformer loads. No pin-compatible drop-in exists because the curve is a functional characteristic, not a mechanical one — all iC60 breakers share the same DIN-rail footprint and terminal layout.

What is A9F07363's listed depth?

The A9F07363 has a depth of 78.5 mm.

What is A9F07363's range?

It belongs to the Schneider Electric Acti9 range.

What compliance documentation does Schneider provide for A9F07363?

The breaker is dual certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. Suitability for isolation is confirmed under both standards. RoHS and REACH compliance documentation is standard for the Acti9 range.

MPN
A9F07363