Skip to main content
Schneider Electric A9F07406 — Miniature Circuit Breakers (MCB)

Schneider A9F07406 Acti9 iC60H MCB, 6 A C-curve 4P, 42 kA

MPNA9F07406
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07406, 4P, 6 A rated, C-curve, 42 kA Icu at 12-133 V AC, DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F07406 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F07406 — Ratings
ParameterValue
Rated current (In)6 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F07406 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F07406 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F07406 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F07406 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

What this MCB delivers for your distribution board

The Schneider A9F07406 is a 4-pole miniature circuit-breaker from the Acti9 iC60H series, rated 6 A with a C-curve trip characteristic.

The 4-pole configuration (4P) protects all live conductors, including the neutral, in a single module. Breaking capacity is specified per voltage: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC — the 10 kA Icn at 400 V per EN/IEC 60898-1 is the rating for domestic-style installations. For industrial panels, the Icu figures per EN/IEC 60947-2 govern the SCCR headroom. Thermal-magnetic trip technology with a separate earth-leakage block option means you can add residual-current protection later without swapping the breaker. The unit is rated for isolation (both standards confirm suitability), so it doubles as a disconnector. Overvoltage category IV and pollution degree 3 suit it for main distribution boards near the service entrance.

Integration and wiring details

Snap-on DIN-rail mounting, 72 mm wide (8 x 9 mm pitches). Tightening torque 2 N·m, strip length 14 mm. The toggle control and trip indicator provide local status at a glance. IP20 finger-safe terminals, suitable for enclosed panel use.

Frequently asked questions

What is the breaking capacity of A9F07406 at 400 V?

At 400 V AC, the Icn per EN/IEC 60898-1 is 10 kA, and the Icu per EN/IEC 60947-2 is 15 kA at 380–415 V and 10 kA at 440 V.

Where can I buy A9F07406 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does A9F07406 carry?

It conforms to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1 and IP20 per IEC 60529.

MPN
A9F07406