Skip to main content
Schneider Electric A9F07406

Schneider A9F07406 Acti9 iC60H MCB, 6 A C-curve 4P, 42 kA

MPN A9F07406
Active

Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07406, 4P, 6 A rated, C-curve, 42 kA Icu at 12-133 V AC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07406 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07406 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

What this MCB delivers for your distribution board

The Schneider A9F07406 is a 4-pole miniature circuit-breaker from the Acti9 iC60H series, rated 6 A with a C-curve trip characteristic.

The 4-pole configuration (4P) protects all live conductors, including the neutral, in a single module. Breaking capacity is specified per voltage: 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC — the 10 kA Icn at 400 V per EN/IEC 60898-1 is the rating for domestic-style installations. For industrial panels, the Icu figures per EN/IEC 60947-2 govern the SCCR headroom. Thermal-magnetic trip technology with a separate earth-leakage block option means you can add residual-current protection later without swapping the breaker. The unit is rated for isolation (both standards confirm suitability), so it doubles as a disconnector. Overvoltage category IV and pollution degree 3 suit it for main distribution boards near the service entrance.

Integration and wiring details

Snap-on DIN-rail mounting, 72 mm wide (8 x 9 mm pitches). Tightening torque 2 N·m, strip length 14 mm. The toggle control and trip indicator provide local status at a glance. IP20 finger-safe terminals, suitable for enclosed panel use.

MPN