Skip to main content
Schneider Electric A9F07463

Schneider Electric A9F07463 Acti9 iC60H MCB, 63 A, 4P, C-Cur

MPN A9F07463
Active

Schneider Electric Acti9 iC60H, A9F07463, miniature circuit breaker, 63 A, 4P, C-curve, 42 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07463 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07463 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07463 is an Acti9 iC60H miniature circuit breaker rated 63 A with a C-curve trip characteristic, 4 protected poles, and a 42 kA ultimate breaking capacity (Icu) at 12–133 V AC.

The 63 A C-curve means the magnetic trip activates at 8 x In ±20 % — roughly 504 A instantaneous — which suits moderate inrush loads like lighting banks, small motor groups, or transformer primaries without nuisance tripping. The 42 kA Icu at low voltage drops to 30 kA at 220–240 V and 15 kA at 380–415 V; that 15 kA at 400 V is the figure to coordinate with downstream branch breakers in a typical European distribution board. Overvoltage category IV and pollution degree 3 mean this breaker is rated for the main incoming supply at the service entrance — not just sub-distribution — in environments with conductive dust or humidity.

Panel integration

IP20 finger-safe terminals are standard for enclosed panels.

MPN