Skip to main content
Schneider Electric A9F07601

Schneider Electric A9F07601 Acti9 iC60H MCB, 1 A C-Curve, 1P

MPN A9F07601
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, 1 A, C-curve, 1P+N, 70 kA Icu at 240 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07601 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07601 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F07601 is an Acti9 iC60H miniature circuit breaker rated 1 A with a C-curve magnetic trip at 8 x In ±20 %, meaning it is sized for protecting a 1 A branch circuit against overload and short-circuit — the C-curve characteristic suits moderate inrush loads such as small motor starters or lighting banks where the start-up surge is not extreme. The 1P+N poles configuration provides overcurrent protection on the phase conductor and a switched neutral, common in single-phase distribution panels where the neutral is not protected but is isolated when the breaker is off. Breaking capacity is 70 kA Icu at 220...240 V AC per EN/IEC 60947-2, which means this breaker can safely interrupt a fault current up to 70 kA without welding its contacts — a high-interrupting rating for a 1 A frame, giving headroom for installation close to a transformer or in a high-fault-current panel. The same unit also carries a 10 kA Icn rating at 230 V per EN/IEC 60898-1, the standard for household and similar installations, so it is dual-certified for both industrial (60947-2) and residential/commercial (60898-1) applications.

The double-terminal design accepts 1...25 mm² rigid or 1...16 mm² flexible conductors, with a tightening torque of 2 N.m and a wire-stripping length of 14 mm.

MPN