Skip to main content
Schneider Electric A9F07620

A9F07620 Acti9 iC60H MCB, C-Curve 20 A 1P+N, 42 kA

MPN A9F07620
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F07620, C-curve, 20 A rated current, 1P+N poles, 42 kA breaking capacity at low voltage, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07620 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F07620 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider A9F07620 is an Acti9 iC60H miniature circuit breaker (MCB) with a C-curve, 20 A rated current, and 1P+N pole configuration. The 42 kA Icu at 12…60 V AC (per EN/IEC 60947-2) tells you this breaker safely interrupts fault currents up to that level at the lowest AC voltages; at 230 V the Icu drops to 15 kA, and the Icn (IEC 60898-1 rating) is 10 kA. That dual certification means it passes both the industrial (60947-2) and residential/light-commercial (60898-1) standards, so it fits either duty class — useful when a panel must meet both specs on the same BOM line. The 1P+N configuration switches the live pole only; the neutral is switched but not protected — verify your circuit's neutral isolation requirement. Thermal-magnetic trip technology combines a bimetal for overload protection and a solenoid for short-circuit response. Overvoltage category IV means it's rated for installation at the service entrance or main distribution board, not just downstream subpanels.

Depth of 78.5 mm and height of 91 mm. IP20 finger-safe front; the terminals themselves are not IP20-rated once wired — plan for finger-duct covers if the panel needs full touch protection.

Lifecycle status is current. This is a standard-production Acti9 iC60H variant.

MPN
A9F07620