Skip to main content
Schneider Electric A9F07625

Schneider A9F07625 Acti9 iC60H MCB, 25 A C-Curve, 1P+N, 42 k

MPN A9F07625
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, 25 A, C-curve, 1P+N, 42 kA Icu at 12-60 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07625 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F07625 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F07625 is a Schneider Acti9 iC60H miniature circuit breaker rated 25 A with a C-curve (magnetic trip at 8 x In ±20 %). At 230 V AC the Icu drops to 15 kA, still a solid figure for most commercial panelboards. Dual-rated to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/installation) standards, so it qualifies for either duty classification — useful when the same BOM covers both plant and facility panels. The 1P+N configuration (one protected pole, switched neutral) fits single-phase branch circuits where neutral isolation is required but overcurrent protection on the neutral isn't needed. The neutral is left-positioned, which matters when wiring a pre-assembled distribution board — verify busbar orientation matches.

Deployment context

IP20 finger protection means it's rated for dry indoor enclosures only — no washdown, no outdoor exposure without a secondary cabinet. The toggle actuator and trip indicator give local visual status without opening the door.

MPN
A9F07625