Schneider Electric A9F08113

Schneider A9F08113 Acti9 iC60H MCB, 1P 13A D Curve, 42 kA

MPN A9F08113
Obsolete

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08113, 1-pole, 13 A rated current, D curve, 42 kA Icu at 12-60 VAC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08113 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08113 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Schneider Electric A9F08113 is a 1-pole Acti9 iC60H miniature circuit breaker rated 13 A with a D tripping curve (12 x In magnetic trip limit, +/- 20 %). It breaks up to 42 kA Icu at 12-60 VAC 50/60 Hz per EN/IEC 60947-2, and 10 kA Icn at 230 VAC per EN/IEC 60898-1. Dual-rated to both standards, so it fits distribution boards (60898-1) and industrial panel feeders (60947-2) in the same slot.

D curve and breaking capacity

The D curve trips magnetically at 12 x In (156 A typical), which avoids nuisance trips on transformer inrush or motor starting — common on DC supply or AC drives with high capacitive charge. DC breaking capacity is 20 kA Icu at 12-60 VDC, 15 kA at 60-72 VDC, making it usable on 48 V battery banks or DC bus distribution. Rated insulation voltage is 500 VAC; overvoltage category IV suits main-panel incoming feeders. Pollution degree 3 (conductive pollution) means it holds up in industrial enclosures without conformal coating.

DIN-rail footprint and wiring

Terminals accept 1-25 mm² rigid or 1-16 mm² flexible, double terminal top and bottom for daisy-chaining. Torque to 2 N·m; strip 14 mm. IP20 finger-safe front, but the terminals need enclosure protection in wet areas.