Skip to main content
Schneider Electric A9F08170

Schneider Electric A9F08170 Acti9 iC60H MCB, 0.5 A, D Curve,

MPN A9F08170
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, 1P, 0.5 A, D curve, 70 kA Icu at 240 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08170 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08170 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08170 is a 1-pole Acti9 iC60H miniature circuit breaker rated at 0.5 A with a D tripping curve. The 70 kA Icu at 220…240 V AC (per EN/IEC 60947-2) gives real fault-current headroom in a panel fed by a large transformer, and the 10 kA Icn at 230 V AC (per EN/IEC 60898-1) covers the residential and light commercial coordination requirement.

The iC60H carries a 70 kA Icu rating at 240 V AC under EN/IEC 60947-2, which is the industrial standard for panelboards and motor control centers. For downstream coordination, the limitation class is 3 per EN/IEC 60898-1, so it restricts let-through energy enough to allow standard downstream MCBs to hold their selectivity under most fault conditions. The 20 kA Icu at 12…60 V DC and 15 kA Icu at 60…72 V DC cover DC control circuits or battery-backed loads, though the 0.5 A rating limits the practical DC load to signal-level or small relay coils.

Mounts on a DIN rail, 18 mm wide (2 modules). The double terminals top and bottom accept 1…25 mm² rigid or 1…16 mm² flexible copper — enough for a 0.5 A circuit's feed and load in standard panel wire. The toggle has a trip-indicator window that shows a red flag when the breaker has tripped on overload or short circuit, which saves a multimeter check during commissioning or troubleshooting. Pollution degree 3 (conforming to EN/IEC 60947-2) means it's rated for the conductive-dust and humidity conditions typical of industrial control panels, not just clean residential switchgear.

MPN
A9F08170