Skip to main content
Schneider Electric A9F08201 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F08201 Acti9 iC60H MCB, D Curve, 1 A, 2

MPNA9F08201
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, D curve, 1 A rated current, 2 poles, 70 kA Icu at 415 V AC, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08201 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F08201 — Electrical
ParameterValue
Rated current [In]1 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F08201 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F08201 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F08201 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F08201 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08201 is an Acti9 iC60H miniature circuit breaker with a D tripping curve, rated 1 A, 2 poles, and a 70 kA Icu breaking capacity at 415 V AC. It's a thermal-magnetic MCB for distribution panels, designed to protect branch circuits against overloads and short circuits.

Breaking capacity is dual-rated: 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V AC per EN/IEC 60898-1. Overvoltage category IV means it's suitable for installation at the origin of the installation, before the main distribution board. The 2-pole version (2P) protects both live conductors. The trip indicator and contact position indicator give visual confirmation of state without needing to measure voltage.

Mounts on a DIN rail, occupies 4 module pitches (36 mm width). Depth is 78.5 mm, height 91 mm. The double terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; strip length is 14 mm.

Frequently asked questions

How do I get current pricing and availability for A9F08201?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

What is the A9F08201's breaking capacity at 415 V?

70 kA Icu at 380–415 V AC per EN/IEC 60947-2. At 400 V AC under EN/IEC 60898-1, the Icn is 10 kA.

What compliance standards does the A9F08201 meet?

It conforms to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. Pollution degree 3 per EN/IEC 60947-2. Overvoltage category IV.

What is the closest alternative to A9F08201 in the Acti9 family?

Within the Acti9 iC60H range, the main variant difference is the tripping curve (B, C, D) and the rated current. The A9F08201 is the 1 A, D-curve, 2-pole version. A B-curve or C-curve at the same current would trip faster on inrush; a higher current rating (e.g., 2 A or 6 A) would shift the overload threshold. No pin-compatible drop-in exists with a different curve — the trip unit is integral.

MPN
A9F08201