Schneider Electric A9F08206 Acti9 iC60H MCB, 6A D-curve 2P

MPNA9F08206
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 6 A, D-curve, 2-pole, 42 kA breaking capacity, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08206 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F08206 — Electrical
ParameterValue
Rated current [In]6 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F08206 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F08206 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F08206 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F08206 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08206 is an Acti9 iC60H miniature circuit breaker rated at 6 A with a D-curve trip characteristic, two protected poles, and a 42 kA breaking capacity at 12–133 V AC.

The 6 A continuous rating is the wire and load limit — this breaker protects a circuit drawing up to 6 A steady. The D-curve's 12 x In magnetic trip (72 A instantaneous) lets it ride through motor-start current without opening, but still clears a hard short fast. Breaking capacity of 42 kA Icu at 12–133 V AC drops to 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V — that's the maximum fault current it can safely interrupt at each voltage level. For a 400 V panel, the 15 kA Icu and 10 kA Icn (per EN/IEC 60898-1) give you solid headroom for most distribution boards. The 2-pole version switches both line and neutral, which matters for single-phase circuits where you want full isolation.

Height is 91 mm, depth 78.5 mm, so it fits a standard distribution board without surprises. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; strip length is 14 mm, torque to 2 N·m. IP20 rated, so it's for inside an enclosure — no washdown exposure. The toggle switch gives local on/off and a trip-indicator flag shows when it's tripped.

Frequently asked questions

Where can I buy A9F08206 and how do I get a price?

The A9F08206 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is A9F08206's breaking capacity at 400 V?

At 380–415 V AC the A9F08206 has a 15 kA Icu per EN/IEC 60947-2, and a 10 kA Icn per EN/IEC 60898-1 at 400 V AC.

What standards does A9F08206 comply with?

The A9F08206 is certified to EN/IEC 60947-2 and EN/IEC 60898-1, covering both industrial and household-style circuit-breaker requirements.

What does the D-curve mean on this breaker?

The D-curve sets the magnetic trip at 12 x In (±20 %), so a 6 A breaker trips instantaneously at roughly 72 A. This suits loads with high inrush current like small motors or transformers.