Skip to main content
Schneider Electric A9F08210

Schneider Electric A9F08210 Acti9 iC60H MCB, 10 A, 2P, D Cur

MPN A9F08210
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08210, 10 A rated current, 2-pole, D curve, 42 kA Icu breaking capacity at 12...133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08210 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08210 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08210 is a 10 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, with a D tripping curve. It is a thermal-magnetic MCB designed for distribution in residential, commercial, and industrial panels. The 2-pole version protects both live conductors in a single-phase or split-phase circuit.

Rated breaking capacity hits 42 kA Icu at 12...133 V AC, 30 kA at 220...240 V, and 15 kA at 380...415 V (all per EN/IEC 60947-2). For the IEC 60898-1 rating, it delivers 10 kA Icn at 400 V AC. That dual-rated coverage means it qualifies for both industrial (60947-2) and domestic (60898-1) applications — useful when a panel must meet both standards. The utilisation category A (EN/IEC 60947-2) confirms it is not intended for motor switching under load; use a contactor for that.

Mounts on a DIN rail. Width is 36 mm (4 x 9 mm pitches). Height 91 mm, depth 78.5 mm. IP20 rated.

MPN
A9F08210