Skip to main content
Schneider Electric A9F08213

Schneider Electric A9F08213 Acti9 iC60H MCB, D Curve, 13 A,

MPN A9F08213
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08213, D curve, 13 A, 2 poles, 42 kA Icu.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08213 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08213 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08213 is a 13 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, with a D tripping curve. The D curve means its magnetic trip threshold is 12 x In (±20 %), so it tolerates the high inrush currents of motor loads, transformers, or discharge lighting without nuisance tripping — a common requirement on plant floors where a standard C curve would drop out on startup.

This breaker carries a 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, and 15 kA at 380–415 V, all per EN/IEC 60947-2. At 400 V AC it is also rated 10 kA Icn per EN/IEC 60898-1. For a 13 A MCB on a typical 400 V distribution board, the 15 kA Icu gives you headroom against high fault currents without cascading upstream — useful when the transformer is close to the panel. The 2-pole version switches both line and neutral, with both poles protected.

Installation and wiring notes

Mounts on DIN rail. The toggle switch provides local on/off control plus a trip indicator for visual fault identification. Pollution degree 3 (industrial environment) and overvoltage category IV (main incoming supply) are built in — no derating needed for typical panel conditions. IP20 rated, so install inside an enclosure.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household and similar), utilisation category A. Suitable for isolation per both standards. Earth-leakage protection requires a separate Vigi block, not integrated.

MPN
A9F08213