Schneider Electric A9F08213 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F08213 Acti9 iC60H MCB, D Curve, 13 A,

MPNA9F08213
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08213, D curve, 13 A, 2 poles, 42 kA Icu.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08213 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F08213 — Electrical
ParameterValue
Rated current [In]13 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F08213 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F08213 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F08213 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F08213 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08213 is a 13 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, with a D tripping curve. The D curve means its magnetic trip threshold is 12 x In (±20 %), so it tolerates the high inrush currents of motor loads, transformers, or discharge lighting without nuisance tripping — a common requirement on plant floors where a standard C curve would drop out on startup.

This breaker carries a 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, and 15 kA at 380–415 V, all per EN/IEC 60947-2. At 400 V AC it is also rated 10 kA Icn per EN/IEC 60898-1. For a 13 A MCB on a typical 400 V distribution board, the 15 kA Icu gives you headroom against high fault currents without cascading upstream — useful when the transformer is close to the panel. The 2-pole version switches both line and neutral, with both poles protected.

Installation and wiring notes

Mounts on DIN rail. The toggle switch provides local on/off control plus a trip indicator for visual fault identification. Pollution degree 3 (industrial environment) and overvoltage category IV (main incoming supply) are built in — no derating needed for typical panel conditions. IP20 rated, so install inside an enclosure.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household and similar), utilisation category A. Suitable for isolation per both standards. Earth-leakage protection requires a separate Vigi block, not integrated.

Frequently asked questions

Where can I buy the A9F08213 and how is it quoted?

The A9F08213 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for volume or single-unit needs.

What is the breaking capacity of the A9F08213?

The A9F08213 has a 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA Icn at 400 V AC, all per EN/IEC 60947-2 and EN/IEC 60898-1 standards.

What does the D curve mean on this MCB?

The D curve means the magnetic trip threshold is 12 x In (±20 %), so the breaker tolerates high inrush currents from motor loads, transformers, or discharge lighting without nuisance tripping.

MPN