Schneider Electric A9F08232 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F08232 Acti9 iC60H MCB, D Curve, 32 A,

MPNA9F08232
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08232, D curve, 32 A, 2 poles, 42 kA breaking capacity, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F08232 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F08232 — Electrical
ParameterValue
Rated current [In]32 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F08232 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F08232 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F08232 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F08232 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08232 is an Acti9 iC60H miniature circuit breaker (MCB) with a D tripping curve, rated 32 A, 2 poles, designed for distribution applications.

Breaking capacity and curve

Breaking capacity reaches 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC (per EN/IEC 60947-2). It also carries a 15 kA Icn at 400 V per EN/IEC 60898-1.

Construction and integration

Housing is white, 36 mm wide (4 x 9 mm pitches), 91 mm tall, 78.5 mm deep — fits standard DIN-rail enclosures. Double terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible wire; tightening torque is 3.5 N·m. IP20 rated for protected indoor panels.

Frequently asked questions

Where can I buy A9F08232?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of A9F08232?

42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, 10 kA at 440 V AC (EN/IEC 60947-2), and 15 kA Icn at 400 V (EN/IEC 60898-1).

What is the magnetic trip threshold?

D curve trips magnetically at 12 x In (±20 %), so it holds through motor inrush and transformer energization.

What standards does A9F08232 comply with?

Complies with EN/IEC 60947-2 and EN/IEC 60898-1, pollution degree 3, overvoltage category IV, and tropicalisation per IEC 60068-1.

MPN