Skip to main content
Schneider Electric A9F08240 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F08240 Acti9 iC60H MCB, 40 A, 2P, D-Cur

MPNA9F08240
Obsolete

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08240, 40 A rated, 2-pole, D-curve, 42 kA breaking capacity, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F08240 — Identification
ParameterValue
Product nameActi9 iC60
Series / familyActi9
Device short nameiC60H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F08240 — Electrical
ParameterValue
Rated current [In]40 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9F08240 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9F08240 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height91 mm
Depth78.5 mm
Mounting supportDIN rail
Terminal connectionsDouble terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F08240 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9F08240 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08240 is a 40 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, with a D-curve trip characteristic. It's built for distribution panels where high inrush loads — motor circuits, transformers, discharge lighting — are the norm. The D-curve means magnetic tripping happens at 12 x In (480 A), so it rides through startup surges without nuisance trips. Rated breaking capacity hits 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V per EN/IEC 60947-2. It also carries a 10 kA Icn at 400 V per EN/IEC 60898-1 for residential or light commercial coordination.

Width is 36 mm (4 x 9 mm pitches), so it takes two adjacent slots in a typical distribution board. Double terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible — enough for a 40 A feed without pigtailing. IP20 finger-safe front, pollution degree 3, overvoltage category IV — rated for main-distribution duty inside a closed panel.

Frequently asked questions

What is A9F08240's breaking capacity at 400 V?

15 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

Where can I buy A9F08240 and how is it quoted?

Sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does this brand provide for A9F08240?

The A9F08240 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries IP20 protection, pollution degree 3, and overvoltage category IV.

MPN
A9F08240