Skip to main content
Schneider Electric A9F08270

Schneider Electric A9F08270 Acti9 iC60H MCB, 0.5 A, D Curve,

MPN A9F08270
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08270, 0.5 A rated current, D curve, 2 poles, 70 kA Icu at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08270 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9F08270 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Integrator note: A9F08270 Acti9 iC60H

The Schneider Electric A9F08270 is a 2-pole miniature circuit breaker from the Acti9 iC60H series, rated 0.5 A with a D tripping curve. The D curve (magnetic tripping limit 12 x In +/- 20 %) means this breaker tolerates high inrush currents — typical for motor, transformer, or lighting ballast loads — without nuisance tripping. At 0.5 A, it protects a small motor or control transformer circuit where the start-up surge exceeds the C-curve threshold. Breaking capacity is 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 15 kA Icn at 400 V AC per EN/IEC 60898-1.

The A9F08270 carries a current lifecycle status from the manufacturer. For audit and tender purposes, the part is listed as suitable for isolation per both standards, and includes a contact position indicator and trip indicator for visual confirmation of status.

The DIN-rail mount and 36 mm width (4 modules) fit standard distribution board layouts. Double terminals top and bottom accept 1…25 mm² rigid or 1…16 mm² flexible conductors; strip length 14 mm, tightening torque 2 N.m. IP20 finger-safe protection is maintained when installed in an enclosed panel. Earth-leakage protection requires a separate block (not integrated), so plan for an external RCCB or RCBO if ground-fault protection is needed on the same circuit.

MPN
A9F08270