A9F08302 Acti9 iC60H MCB, D Curve 2 A 3P, 70 kA Icu

MPNA9F08302
Obsolete

Schneider Electric Acti9 iC60H, A9F08302, miniature circuit-breaker, D curve, 2 A rated current, 3 poles, 70 kA Icu breaking capacity at 415 V AC, DIN rail mount, thermal-magnetic trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08302 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08302 — Ratings
ParameterValue
Rated current (In)2 A
Poles configuration3P
Number of protected poles3
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08302 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08302 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08302 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08302 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F08302 is a Schneider Electric Acti9 iC60H miniature circuit-breaker, a 3-pole unit rated at 2 A with a D tripping curve. The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits. For a 2 A rating, this holds the unit on the grid for steady-state loads up to 2 A and trips fast on a fault, provided the prospective short-circuit current stays within the 70 kA Icu envelope at 415 V.

The iC60H designation means this breaker sits in the high-breaking-capacity tier of the Acti9 iC60 family. At 380…415 V AC the Icu is 70 kA; at 440 V it drops to 50 kA, and at 400 V the Icn (service breaking capacity per EN/IEC 60898-1) is 10 kA. For a panel designer coordinating downstream MCBs, the 70 kA Icu figure gives headroom for high-fault installations — large distribution transformers or industrial switchboards — provided the upstream protective device limits let-through energy to what the 2 A D-curve can withstand. The limitation class is 3 per EN/IEC 60898-1, meaning it restricts peak let-through current and I²t, which helps with cascading and reduces arc-flash energy on the load side.

Mounts on DIN rail — the 9 mm pitch count is 6, so the breaker occupies 6 modules (54 mm). IP20 finger-safe front. The toggle control has a trip indicator that shows a red flag when the breaker has tripped on fault — useful for a field-service tech walking a panel to find which circuit dropped. Stripping length is 14 mm; torque the terminals to 2 N·m.

Frequently asked questions

What are the key ratings for the A9F08302?

Rated current 2 A, D curve (magnetic trip at 12 x In), 3 poles, breaking capacity 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V AC per EN/IEC 60898-1. Rated insulation voltage 500 V AC.

What standards does the A9F08302 comply with?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Suitability for isolation is confirmed per both standards. Pollution degree 3, overvoltage category IV.

Where can I buy the A9F08302?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.