Skip to main content
Schneider Electric A9F08303 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F08303 Acti9 iC60H MCB, 3A Curve D, 3P

MPNA9F08303
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08303, 3A rated current, Curve D, 3-pole, 70 kA breaking capacity at 400 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08303 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08303 — Ratings
ParameterValue
Rated current (In)3 A
Poles configuration3P
Number of protected poles3
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08303 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08303 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08303 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08303 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08303 is an Acti9 iC60H miniature circuit breaker (MCB) rated for 3 A with a D tripping curve, configured as a 3-pole unit. Breaking capacity reaches 70 kA Icu at 380…415 V AC and 50 kA Icu at 440 V AC per EN/IEC 60947-2, with an Icn of 10 kA at 400 V AC per EN/IEC 60898-1. This dual-rated MCB satisfies both the performance (60947-2) and residential/commercial (60898-1) standards, giving the specifier flexibility in panel design.

Mounts on standard DIN rail. The 3-pole body occupies 6 x 9 mm pitches (54 mm width). Depth of 78.5 mm and height of 91 mm fit within typical distribution board envelopes. Terminals accept 1…25 mm² rigid or 1…16 mm² flexible conductors; tightening torque is 2 N.m. IP20 finger protection is standard for the enclosure.

The thermal-magnetic trip unit provides a magnetic threshold of 12 x In (±20 %). For a 3 A MCB, this means magnetic pickup occurs between approximately 28.8 A and 43.2 A. The D curve is selected where load inrush exceeds the C-curve range — for example, small motors, solenoid banks, or power supplies with high capacitive start-up.

Compliance documentation traceability

It is suitable for isolation per both standards. Pollution degree 3 (industrial environment) and overvoltage category IV support installation at the service entrance or main distribution board.

Frequently asked questions

What is the breaking capacity of the A9F08303?

The A9F08303 delivers 70 kA Icu at 380…415 V AC and 50 kA Icu at 440 V AC per EN/IEC 60947-2, with an Icn of 10 kA at 400 V AC per EN/IEC 60898-1.

What does the D curve mean on this MCB?

The D curve has a magnetic trip threshold of 12 x In (±20 %), meaning the breaker tolerates higher inrush currents than B or C curves, making it suitable for motor, transformer, or power-supply loads.

Where can I source the A9F08303 for a BOM line?

The A9F08303 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What compliance standards does the A9F08303 meet?

It is certified to EN/IEC 60947-2 and EN/IEC 60898-1, suitable for isolation, and rated for pollution degree 3 and overvoltage category IV.

MPN