Schneider Electric A9F08306 Acti9 iC60H MCB, D Curve 6 A 3P

MPNA9F08306
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08306, D curve, 6 A rated current, 3 poles, 42 kA Icu breaking capacity at 12-133 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F08306 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08306 — Ratings
ParameterValue
Rated current (In)6 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08306 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08306 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08306 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08306 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F08306 is a Schneider Electric Acti9 iC60H miniature circuit breaker (MCB) with a D tripping curve, rated 6 A and 3 poles. That 6 A rating is the continuous current it carries in free air at 30 °C; on a DIN-rail panel with several breakers ganged, expect some thermal derating, but the iC60H design handles that well within the 20,000 mechanical cycles.

Breaking capacity and isolation

Breaking capacity is 42 kA Icu at 12-133 V AC and 30 kA at 220-240 V AC, dropping to 15 kA at 380-415 V AC and 10 kA at 440 V AC (per EN/IEC 60947-2). Under EN/IEC 60898-1 it's rated 10 kA Icn at 400 V AC. That 42 kA figure at low voltage matters for high-fault panels fed by a large transformer — the breaker stays intact and clears without upstream coordination. It's also certified for isolation (both standards), so it doubles as a visible disconnect when the toggle is off.

Mounts on a DIN rail, 54 mm wide (6 x 9 mm pitches), 91 mm tall, 78.5 mm deep — fits standard distribution boards and enclosure cutouts. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible on both top and bottom, with a double-terminal design for daisy-chaining. IP20 rated, so it's for dry indoor panels only. The white housing with a trip-indicator window makes faulted-pole identification quick during troubleshooting.

Frequently asked questions

Where can I buy A9F08306?

The part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of A9F08306?

Breaking capacity is 42 kA Icu at 12-133 V AC, 30 kA at 220-240 V AC, 15 kA at 380-415 V AC, and 10 kA at 440 V AC per EN/IEC 60947-2, plus 10 kA Icn at 400 V AC per EN/IEC 60898-1.

What compliance documentation does Schneider provide for A9F08306?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1 standards, with IP20 protection per IEC 60529, tropicalisation class 2 per IEC 60068-1, and pollution degree 3 per EN/IEC 60947-2.

MPN