Schneider Electric A9F08306 Acti9 iC60H MCB, D Curve 6 A 3P

MPN A9F08306
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F08306, D curve, 6 A rated current, 3 poles, 42 kA Icu breaking capacity at 12-133 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08306 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08306 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F08306 is a Schneider Electric Acti9 iC60H miniature circuit breaker (MCB) with a D tripping curve, rated 6 A and 3 poles. That 6 A rating is the continuous current it carries in free air at 30 °C; on a DIN-rail panel with several breakers ganged, expect some thermal derating, but the iC60H design handles that well within the 20,000 mechanical cycles.

Breaking capacity and isolation

Breaking capacity is 42 kA Icu at 12-133 V AC and 30 kA at 220-240 V AC, dropping to 15 kA at 380-415 V AC and 10 kA at 440 V AC (per EN/IEC 60947-2). Under EN/IEC 60898-1 it's rated 10 kA Icn at 400 V AC. That 42 kA figure at low voltage matters for high-fault panels fed by a large transformer — the breaker stays intact and clears without upstream coordination. It's also certified for isolation (both standards), so it doubles as a visible disconnect when the toggle is off.

Mounts on a DIN rail, 54 mm wide (6 x 9 mm pitches), 91 mm tall, 78.5 mm deep — fits standard distribution boards and enclosure cutouts. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible on both top and bottom, with a double-terminal design for daisy-chaining. IP20 rated, so it's for dry indoor panels only. The white housing with a trip-indicator window makes faulted-pole identification quick during troubleshooting.