Skip to main content
Schneider Electric A9F08310 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F08310 Acti9 iC60H MCB, D Curve, 10 A,

MPNA9F08310
Active

Schneider Electric Acti9 iC60H, A9F08310, miniature circuit breaker, D curve, 10 A rated current, 3 poles, 42 kA breaking capacity, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F08310 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F08310 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration3P
Number of protected poles3
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F08310 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F08310 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6
A9F08310 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F08310 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F08310 is an Acti9 iC60H miniature circuit breaker — D curve, 10 A, 3-pole, thermal-magnetic trip. It's a current-production part, still actively manufactured and available through distribution. Rated 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V AC per EN/IEC 60947-2. Also carries a 15 kA Icn at 400 V per EN/IEC 60898-1. That dual-standard rating means it's certified for both industrial (60947-2) and residential/commercial (60898-1) installations — useful if the panel crosses jurisdictions or the spec calls for either standard. D curve with magnetic tripping at 12 x In ±20% — so it holds through motor inrush and transformer energization without nuisance trips. The 10 A rating handles lighting, control transformers, and smaller motor branch circuits. Thermal-magnetic element gives short-circuit plus overload protection in one package.

Snaps onto DIN rail, 6 x 9 mm pitch modules wide (54 mm). Depth 78.5 mm, height 91 mm. That footprint fits standard distribution boards and subpanels — no oddball dimensions to fight. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; torque to 2 N·m. Wire strip length 14 mm. IP20 finger-safe front, pollution degree 3 rated. Overvoltage category IV — suitable for main incoming panels, not just sub-distribution.

Suitability for isolation is confirmed under both standards — it's a legitimate disconnecting means. Separate earth-leakage block available if you need RCD integration downstream.

Frequently asked questions

Where can I buy A9F08310 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is A9F08310's listed depth?

78.5 mm deep, 54 mm wide (6 x 9 mm pitch modules), 91 mm tall. Standard DIN-rail footprint.

What compliance documentation does this brand provide for A9F08310?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Suitability for isolation confirmed under both standards. IP20 per IEC 60529, pollution degree 3, overvoltage category IV. Tropicalisation class 2 per IEC 60068-1.

MPN
A9F08310