Skip to main content
Schneider Electric A9F08313

Schneider Electric A9F08313 Acti9 iC60H MCB, 13 A, D Curve,

MPN A9F08313
Active

Schneider Electric Acti9 iC60H, A9F08313, miniature circuit breaker, 13 A, D curve, 3P, 42 kA Icu at 12-133 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08313 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F08313 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F08313 is a 13 A D-curve miniature circuit breaker from the Acti9 iC60H series, 3-pole, rated for both AC and DC networks. The D curve means magnetic tripping occurs at 12 x In (156 A) with a +/-20% tolerance — so it handles the inrush of motor loads, transformers, or capacitive banks without nuisance trips on start-up. The 42 kA Icu at 12-133 V AC (EN/IEC 60947-2) is its ultimate breaking capacity; at 220-240 V AC that drops to 30 kA, and at 380-415 V AC to 15 kA. At the distribution-board voltage of 400 V AC, the Icn per EN/IEC 60898-1 is 10 kA — the figure that governs residential and light commercial panel coordination. The thermal-magnetic trip unit covers overload (thermal bimetal) and short-circuit (solenoid) in one package, with a separate earth-leakage block available if needed.

Depth is 78.5 mm, height 91 mm — check gland-plate clearance if the enclosure is shallow.

Lifecycle stage is current — no end-of-life notice on record. For a BOM freeze or line-down spare, the 13 A D-curve in 3P is a standard catalogue item, so supply continuity is predictable. No official successor exists because none is needed.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/ commercial) — covers both the panel builder's coordination study and the final installation standard. Suitability for isolation confirmed under both standards. Contact position indicator and trip indicator give visual confirmation without opening the panel.

MPN