Skip to main content
Schneider Electric A9F43403

Schneider Electric A9F43403 Acti9 iC60N MCB, 3 A, 4P, B Curv

MPN A9F43403
Obsolete

Schneider Electric Acti9 iC60N, A9F43403, miniature circuit breaker, 4P, 3 A, B curve, 50 kA breaking capacity at 415 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F43403 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F43403 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F43403 is an Acti9 iC60N miniature circuit breaker (MCB) with four protected poles, rated 3 A, B-curve tripping characteristic, and a 50 kA breaking capacity at 415 V AC. It clips onto a standard DIN rail — the 72 mm wide body (9 module pitches at 9 mm each) fits a panel cutout the same way every iC60N does, so if you're swapping an older 4P unit the footprint is a straight drop-in. Rated 3 A continuous, the B curve trips magnetically between 3.2 A and 3.6 A (4 x In ±20 %), which means it clears short-circuit faults fast on predominantly resistive or lighting loads where inrush isn't an issue. For a 4-pole breaker at this current, the thermal-magnetic trip unit handles overloads on all poles simultaneously.

The 50 kA Icu at 380…415 V AC (EN/IEC 60947-2) is the headline number — it tells you this breaker can interrupt a 50 kA prospective fault current without welding its contacts, which is essential for high-fault panels close to the transformer. The same unit also carries a 10 kA Icn at 415 V per EN/IEC 60898-1, the domestic/commercial standard. Dual-rated like this means it's accepted in both industrial (60947-2) and building (60898-1) installations without a separate part number.

Panel integration

The 78.5 mm depth leaves clearance behind a standard 80 mm deep enclosure; the 85 mm height fits under a 90 mm top gland plate. Terminals accept 1…25 mm² rigid or 1…16 mm² flexible — strip 14 mm, torque to 2 N·m. IP20 finger-safe terminals.

MPN