Skip to main content
Schneider Electric A9F45402

Schneider Electric A9F45402 Acti9 iC60N MCB, D Curve, 2 A, 4

MPN A9F45402
Obsolete

Schneider Electric Acti9 iC60N, A9F45402, miniature circuit breaker, 4P, D curve, 2 A, 50 kA breaking capacity, clip-on rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F45402 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F45402 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The A9F45402 is a 4-pole Acti9 iC60N miniature circuit breaker rated 2 A with a D curve, meaning the magnetic trip operates at 12 x In (24 A) plus or minus 20%. The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits. Dual-rated to EN/IEC 60898-1 and EN/IEC 60947-2, so it qualifies for both domestic-distribution and industrial panel applications.

Depth 78.5 mm, height 85 mm. The 4-pole form factor with a single neutral and three protected poles means it fits a 4-wire three-phase distribution board. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible, stripped to 14 mm, torqued to 2 N·m. IP20 finger-safe front; padlockable for lockout-tagout. The white housing with a toggle actuator and trip indicator is standard Acti9 family appearance.

D curve selection logic

The D curve (12 x In magnetic trip) distinguishes this from the more common B (3–5 x In) or C (5–10 x In) variants in the same iC60N family. For a 2 A rating, the D curve holds through a 24 A peak before the magnetic element fires — that is the deciding factor for transformer primary protection or contactor coil circuits where the inrush lasts several cycles. If the load is resistive or general-purpose with no high inrush, a C curve would trip faster on fault; but for motorized or inductive loads, D is the correct call.

MPN
A9F45402