Skip to main content
Schneider Electric A9F56103 — 1-Pole MCB (DIN Rail)

Schneider Electric A9F56103 Acti9 IKQ MCB, 3A B-Curve 1P 10k

MPNA9F56103
Obsolete

Schneider Electric Acti9 IKQ miniature circuit breaker, A9F56103, 1P, 3 A rated, B-curve, 10 kA Icn at 240 V AC, thermal-magnetic trip, EN/IEC 60898-1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F56103 — Identification
ParameterValue
Product nameIKQ
Product / component typeCircuit breaker
Product rangeActi9
Poles description1P
Number of protected poles1
A9F56103 — Electrical & Protection
ParameterValue
Rated current (In)3 A
Rated operational voltage (Ue)240 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to EN 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9F56103 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeSingle terminal (bottom) 1...25 mm² rigid Single terminal (bottom) 1...16 mm² flexible
Mounting supportRail
Mounting modePlug-on
Width18 mm
Height85 mm
Depth78.5 mm
Tightening torque (by circuit)2 N.m bottom
A9F56103 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9F56103 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9F56103 — Electrical
ParameterValue
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60898-1

Product details

The A9F56103 is a 1-pole Acti9 IKQ miniature circuit breaker rated 3 A with a B-curve, meaning its magnetic trip activates between 3 and 5 times the rated current (9–15 A). The 10 kA breaking capacity (Icn at 240 V AC, 50/60 Hz, per EN 60898-1) tells you this MCB can safely interrupt a fault current up to 10,000 A at the panel voltage; for most commercial and light industrial distribution boards fed by a transformer of typical impedance, that is enough to clear a bolted fault without the upstream device having to back it up.

The bottom terminal accepts 1–25 mm² rigid or 1–16 mm² flexible, with a tightening torque of 2 N·m and a wire strip length of 14 mm. A padlock provision and trip indicator are built into the toggle — useful for lockout/tagout on a lighting or control circuit where you need visual confirmation the breaker is open.

MPN