Schneider Electric A9F68116 — 1-Pole MCB (DIN Rail)

Schneider Electric A9F68116 Acti9 iT60 MCB, 16 A, C-Curve, 1

MPNA9F68116
Obsolete

Schneider Electric Acti9 iT60, A9F68116, miniature circuit breaker, 1P, 16 A, C-curve, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68116 — Identification
ParameterValue
Product nameActi9 iT60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short nameiT60N
Poles description1P
Number of protected poles1
Device applicationDistribution
A9F68116 — Electrical & Protection
ParameterValue
Rated current (In)16 A
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu / AIR)36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
A9F68116 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Width18 mm
Tightening torque (by circuit)2 N.m top or bottom
A9F68116 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
A9F68116 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2 EN/IEC 60898-1
A9F68116 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

The Schneider Electric A9F68116 is a 1-pole Acti9 iT60 miniature circuit breaker rated 16 A with a C-curve trip characteristic.

Breaking capacity and application

Rated breaking capacity reaches 36 kA Icu at 12-60 V AC (EN/IEC 60947-2), stepping down to 10 kA Icu at 220-240 V AC and 6 kA Icn at 230 V AC under the 60898-1 standard. This gives the A9F68116 headroom for high-fault panels where a standard 6 kA or 10 kA MCB would not coordinate. The C-curve (8 x In +/- 20% magnetic trip) suits moderate inrush loads such as small motor circuits, lighting banks, or distribution subfeeds.

Removable comb busbar installed. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible cable; tightening torque 2 N.m. IP20 B finger-safe protection. The thermal-magnetic trip unit is non-interchangeable — select the rating at BOM freeze.

Frequently asked questions

Who supplies A9F68116 and how is it quoted for volume purchases?

A9F68116 is sourced through independent distribution channels. Availability and current pricing are confirmed at quote time against an RFQ; submit a request for volume pricing and lead time.

What is A9F68116's rated current and trip curve?

The A9F68116 is rated 16 A with a C-curve (magnetic trip at 8 x In +/- 20%), suitable for moderate inrush loads.

What compliance documentation does Schneider provide for A9F68116?

The A9F68116 carries dual certification to EN/IEC 60947-2 and EN/IEC 60898-1, with documented isolation suitability, pollution degree 3, overvoltage category IV, and tropicalisation class 2. A declaration of conformity is available from Schneider Electric.

MPN