Schneider Electric A9F68202 — 2-Pole MCB (DIN Rail)

A9F68202 Acti9 iT60 MCB, 2 A C-Curve, 2P, 50 kA

MPNA9F68202
Active

Schneider Electric Acti9 iT60 miniature circuit breaker, 2 A rated, C-curve, 2-pole, 36 mm wide, 50 kA breaking capacity at 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F68202 — Identification
ParameterValue
Product nameActi9 iT60
Series / familyActi9
Device short nameiT60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F68202 — Electrical
ParameterValue
Rated current [In]2 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
A9F68202 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
A9F68202 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Terminal connectionsSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F68202 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 %
A9F68202 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

With a 50 kA breaking capacity at 400 V AC (Icu per EN/IEC 60947-2) and 10 kA Icn per EN/IEC 60898-1, this MCB can interrupt high fault currents upstream, preserving selectivity in a distribution board. The 2-pole (2P) configuration isolates both phase and neutral, which is standard for single-phase circuits where full disconnection is required.

Deployment context

The removable comb busbar system simplifies daisy-chaining multiple breakers in a panel.

Frequently asked questions

What is the breaking capacity of A9F68202 at 400 V?

50 kA Icu at 380–415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V per EN/IEC 60898-1.

Where can I buy A9F68202 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the C-curve trip threshold for A9F68202?

Magnetic tripping occurs at 8 x In ±20%, so for a 2 A rating the instantaneous trip starts between 12.8 A and 19.2 A.

MPN
A9F68202