Schneider Electric A9F68250 — 2-Pole MCB (DIN Rail)

Schneider Electric A9F68250 Acti9 iT60 MCB, C-Curve 50A 2P 3

MPNA9F68250
Obsolete

Schneider Electric Acti9 iT60N miniature circuit breaker, A9F68250, 2P, C-curve 50 A, 36 mm wide, thermal-magnetic trip, dual-standard EN/IEC 60947-2 & 60898-1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F68250 — Identification
ParameterValue
Product nameActi9 iT60
Series / familyActi9
Device short nameiT60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9F68250 — Electrical
ParameterValue
Rated current [In]50 A
Number of protected poles2
Pole configuration2P
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9F68250 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC
Energy limitation class3 conforming to EN/IEC 60898-1
Suitable for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
A9F68250 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Terminal connectionsSingle terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Local signalling / indicationTrip indicator
Contact position indicatorYes
A9F68250 — Environmental
ParameterValue
Operating temperature range-35...70 °C
Storage temperature range-40...85 °C
Relative humidity95 %
A9F68250 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F68250 is a 2-pole miniature circuit breaker from the Acti9 iT60 series, rated 50 A with a C-curve trip characteristic. The thermal-magnetic trip unit protects against overload and short-circuit, and the toggle switch includes a trip-indicator flag for quick fault identification on the panel face.

This breaker carries dual-standard certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar), so its breaking capacity is stated under both. Under 60947-2, the ultimate breaking capacity (Icu) reaches 36 kA at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V. Under 60898-1, the rated short-circuit capacity (Icn) is 10 kA at 400 V. For a typical 230/400 V distribution panel, the 10 kA Icu at 415 V gives you headroom above the standard 6 kA domestic requirement — useful for industrial sub-distribution where fault levels run higher. The limitation class is 3 per EN/IEC 60898-1, meaning it limits let-through energy enough to protect downstream equipment in most residential and light commercial installations.

C-curve and coordination

The C-curve magnetic trip fires at 8 x In (±20%), so the 50 A breaker trips instantaneously between roughly 320 A and 480 A. The utilisation category is A (non-selectivity for short-circuit with downstream breakers), so for full selectivity you'd coordinate upstream with a higher-rated or time-delayed device.

Installation and wiring notes

Mounts on DIN rail with a removable comb busbar for daisy-chaining phases. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible wire; strip length is 14 mm. The IP20 B finger-safe terminals are fine for enclosed panels — no special shrouding needed. Ambient operating range is -35 to 70 °C, storage -40 to 85 °C, with 95% relative humidity and tropicalisation level 2 per EN/IEC 60068-2-78.

Frequently asked questions

What is the breaking capacity of the A9F68250 at 400 V?

Under EN/IEC 60898-1 the Icn is 10 kA at 400 V AC. Under EN/IEC 60947-2 the Icu is 10 kA at 380–415 V AC and 6 kA at 440 V AC.

What is the closest alternative to the A9F68250 in the Acti9 family?

Within the Acti9 iT60 range, the closest peer is the same breaker with a different current rating or pole count. For a 50 A 2-pole C-curve, this is the standard offering; no pin-compatible drop-in from another series exists without checking the busbar and terminal layout.

Where can I buy the A9F68250 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time estimate.

What compliance documentation does the A9F68250 carry?

It is dual-certified to EN/IEC 60947-2 and EN/IEC 60898-1. The IP20 B rating conforms to IEC 60529. Tropicalisation level 2 conforms to EN/IEC 60068-2-78. Pollution degree 3 and overvoltage category IV per IEC 60947-2 are also declared.