Schneider Electric A9F68402

Schneider Electric A9F68402 Acti9 iT60 MCB, 2A C-Curve 4P 50

MPN A9F68402
Active

Schneider Electric Acti9 iT60N, A9F68402, miniature circuit breaker, 4P, 2 A, C-curve, 50 kA Icu at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68402 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width72 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68402 is an Acti9 iT60N miniature circuit breaker — 4 poles, 2 A rated current, C-curve. That dual rating means it fits a distribution board or an industrial sub-panel without re-certifying the assembly.

This breaker delivers 50 kA Icu at 415 V AC (50/60 Hz) under EN/IEC 60947-2, and 10 kA Icn at 400 V under EN/IEC 60898-1. For most industrial panels fed by a transformer of 1 MVA or less, 50 kA gives you solid headroom for selectivity coordination downstream. At 440 V it still holds 25 kA, so you're covered on 480 V-class systems.

C-curve trip and 2 A rating — what it protects

For a 2 A breaker, that's 10 to 20 A instantaneous — ideal for general-purpose distribution loads like lighting, small transformers, or control circuits that don't have a high inrush. The 2 A rating is on the low side; you'd use it to protect a 0.5 kVA control transformer or a string of PLC power supplies, not a motor branch.

Width is 72 mm — that's 8 modules of 9 mm pitch, so it takes up 8 TE (terminal unit) spaces in an enclosure.

MPN
A9F68402