Schneider Electric A9F68410 Acti9 iT60 MCB, 10 A C-Curve 4P

MPN A9F68410
Active

Schneider Electric Acti9 iT60, A9F68410, miniature circuit breaker, 10 A rated current, C-curve, 4 poles, 72 mm width, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68410 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width72 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68410 is an Acti9 iT60 miniature circuit breaker rated at 10 A with a C-curve magnetic trip characteristic, 4 poles, and a 72 mm width for DIN-rail mounting in distribution panels.

The breaking capacity table is the main thing to check against your fault study. At 220…240 V AC this breaker interrupts 20 kA Icu per EN/IEC 60947-2, and at 380…415 V AC it holds 10 kA Icu. The IEC 60898-1 rating is 10 kA Icn at 400 V AC. If your calculated fault level sits above 10 kA at 400 V, this breaker still coordinates because the 60947-2 Icu at that voltage is the same 10 kA — no hidden gap. The 36 kA Icu at 12…133 V AC is a low-voltage edge case for control transformers or battery-backed DC buses.

Trip curve and coordination

C-curve means the magnetic trip fires at 8 x In ±20 %, so for this 10 A breaker the instantaneous trip threshold sits between 64 A and 96 A. That suits general-purpose distribution loads — lighting, small motor starters, control transformers — where the inrush is moderate but not as high as a motor-starting D-curve would handle. The limitation class is 3 per EN/IEC 60898-1, meaning it limits let-through energy enough to protect downstream wiring under short-circuit conditions without cascading the trip upstream. Thermal-magnetic trip unit, no earth-leakage module built in.

Snaps onto DIN rail, 72 mm wide (8 x 9 mm pitches). The removable comb busbar is installed from the factory, so you can daisy-chain phases across adjacent breakers without extra wiring. Terminals accept 1…25 mm² rigid or 1…16 mm² flexible on top or bottom; strip length 14 mm, torque to 2 N·m.