Schneider Electric A9F68410 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F68410 Acti9 iT60 MCB, 10 A C-Curve 4P

MPNA9F68410
Active

Schneider Electric Acti9 iT60, A9F68410, miniature circuit breaker, 10 A rated current, C-curve, 4 poles, 72 mm width, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9F68410 — Identification
ParameterValue
Product nameActi9 iT60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F68410 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration4P
Number of protected poles4
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC/DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F68410 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
A9F68410 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeRemovable comb busbar installed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Number of 9 mm pitches8
A9F68410 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 B conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 %
Tropicalisation class2 conforming to EN/IEC 60068-2-78
A9F68410 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F68410 is an Acti9 iT60 miniature circuit breaker rated at 10 A with a C-curve magnetic trip characteristic, 4 poles, and a 72 mm width for DIN-rail mounting in distribution panels.

The breaking capacity table is the main thing to check against your fault study. At 220…240 V AC this breaker interrupts 20 kA Icu per EN/IEC 60947-2, and at 380…415 V AC it holds 10 kA Icu. The IEC 60898-1 rating is 10 kA Icn at 400 V AC. If your calculated fault level sits above 10 kA at 400 V, this breaker still coordinates because the 60947-2 Icu at that voltage is the same 10 kA — no hidden gap. The 36 kA Icu at 12…133 V AC is a low-voltage edge case for control transformers or battery-backed DC buses.

Trip curve and coordination

C-curve means the magnetic trip fires at 8 x In ±20 %, so for this 10 A breaker the instantaneous trip threshold sits between 64 A and 96 A. That suits general-purpose distribution loads — lighting, small motor starters, control transformers — where the inrush is moderate but not as high as a motor-starting D-curve would handle. The limitation class is 3 per EN/IEC 60898-1, meaning it limits let-through energy enough to protect downstream wiring under short-circuit conditions without cascading the trip upstream. Thermal-magnetic trip unit, no earth-leakage module built in.

Snaps onto DIN rail, 72 mm wide (8 x 9 mm pitches). The removable comb busbar is installed from the factory, so you can daisy-chain phases across adjacent breakers without extra wiring. Terminals accept 1…25 mm² rigid or 1…16 mm² flexible on top or bottom; strip length 14 mm, torque to 2 N·m.

Frequently asked questions

What is the breaking capacity of the A9F68410 at 400 V AC?

At 380…415 V AC the breaking capacity is 10 kA Icu per EN/IEC 60947-2, and the IEC 60898-1 rating is 10 kA Icn at 400 V AC.

What standards does the A9F68410 comply with?

It is certified to both EN/IEC 60947-2 and EN/IEC 60898-1, covering industrial feeder and branch-circuit overcurrent protection.

How do I get pricing and availability for the A9F68410?

Submit an RFQ through this listing; availability and current pricing are confirmed at quote time through independent distribution channels.