Specifications

A9F78132 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F78132 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F78132 is an Acti9 iC60N miniature circuit breaker — a 1-pole, 32 A, B-curve unit built for distribution panels where you need fast tripping on short circuits but a bit of headroom on inrush. The B-curve (4 x In magnetic trip limit, +/- 20 %) means it holds through moderate motor or transformer starts but clears quickly on a hard fault. For residential or light commercial branch circuits rated at 230 V, the IEC 60898-1 Icn is 6 kA, which is the standard domestic fault level.

Terminals accept 1-35 mm² rigid or 1-25 mm² flexible, with a 3.5 N.m torque spec. Strip length 14 mm. That 35 mm² top-end means you can land a fat feeder cable without pigtails. IP20 rated, so keep it behind a panel door or in a cabinet.

MPN