Skip to main content
Schneider Electric A9F87432 — Miniature Circuit Breakers (MCB)

Schneider Electric A9F87432 Acti9 iC60H MCB, 32 A, 4P, C-Cur

MPNA9F87432
Active

Schneider Electric Acti9 iC60H, A9F87432, miniature circuit breaker, 32 A, 4P, C-curve, 42 kA Icu at 133 V AC, thermal-magnetic, DIN rail.

$107.87Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9F87432 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution
A9F87432 — Ratings
ParameterValue
Rated current (In)32 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV
A9F87432 — Protection
ParameterValue
Curve codeC
Trip unit technologyThermal-magnetic
Magnetic tripping limit8 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles
A9F87432 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeSingle terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible
Terminal tightening torque3.5 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height85 mm
Depth78.5 mm
Number of 9 mm pitches8
A9F87432 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1
A9F87432 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The Schneider Electric A9F87432 is a 32 A, 4-pole miniature circuit breaker from the Acti9 iC60H series.

Rated Icu of 42 kA at 12…133 V AC and 30 kA at 220…240 V AC, dropping to 15 kA at 380…415 V AC and 10 kA at 440 V AC. That high interrupt rating at low voltage makes it a strong pick for sub-distribution boards close to large transformers where fault current is stiff. It carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), so it qualifies for both panel builder and final distribution duty.

Snaps onto standard DIN rail — 9 mm pitch occupies 8 modules (72 mm wide). Terminals accept 1…35 mm² rigid or 1…25 mm² flexible, with a stripping length of 14 mm and tightening torque of 3.5 N.m. IP20 finger-safe front; pollution degree 3 rated, so it handles non-condensing conductive environments inside an enclosure.

Frequently asked questions

Where can I buy A9F87432 and get a price?

The A9F87432 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time.

What is the breaking capacity of A9F87432?

Breaking capacity is 42 kA Icu at 12…133 V AC, 30 kA at 220…240 V AC, 15 kA at 380…415 V AC, and 10 kA at 440 V AC per EN/IEC 60947-2. It also carries a 10 kA Icn rating at 400 V per EN/IEC 60898-1.

What standards does A9F87432 comply with?

Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Also carries NF quality label and tropicalisation class 2 per IEC 60068-1.

What is the depth of A9F87432?

Depth is 78.5 mm, height 85 mm, width 72 mm (8 x 9 mm pitches). Fits standard DIN-rail enclosures.

MPN