Schneider Electric A9FDB625 — 1-Pole MCB (DIN Rail)

Schneider Electric A9FDB625 Acti9 iDPN N Arc, 25 A, 6 kA

MPNA9FDB625
Obsolete

Schneider Electric Acti9 iDPN N Arc arc fault detection circuit breaker, A9FDB625, 25 A rated current, C-curve, 6 kA Icn at 230 V AC, 1P+N, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9FDB625 — Identification
ParameterValue
Product nameActi9 iDPN N Arc
Product / component typeArc fault detection circuit breaker
Product rangeActi9
Device short nameiDPN N Arc
Poles description1P + N
Number of protected poles1
A9FDB625 — Electrical & Protection
ParameterValue
Rated current (In)25 A at 30 °C
Rated operational voltage (Ue)230 V AC 50 Hz conforming to IEC 62606 230 V AC 50 Hz conforming to EN/IEC 60898-1
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50 Hz
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9FDB625 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal for 1 cable(s) 10 mm² flexible Tunnel type terminal for 2 cable(s) 2.5 mm² flexible Tunnel type terminal for 1 cable(s) 16 mm² rigid Tunnel type terminal for 2 cable(s) 2.5 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width36 mm
Height81 mm
Depth72 mm
Tightening torque (by circuit)2 N.m
A9FDB625 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9FDB625 — Approvals
ParameterValue
Conformity standardsEN/IEC 62606 IEC 60898-1
A9FDB625 — Electrical
ParameterValue
[Ui] rated insulation voltage400 V AC
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60898-1

Product details

Rated 25 A at 30 °C with a C-curve thermal-magnetic trip unit, it interrupts fault currents up to 6 kA Icn at 230 V AC 50 Hz, complying with both EN/IEC 62606 for arc-fault detection and IEC 60898-1 for MCB performance.

The magnetic trip threshold is set at 5 to 10 times In (125–250 A for this 25 A unit), giving the C-curve characteristic that handles moderate inrush from motor loads or capacitive circuits without nuisance tripping. Electrical durability is rated at 10,000 cycles at 230 V AC; mechanical durability at 20,000 cycles. Tropicalisation to severity B per IEC 60068-2-30 (28-day damp heat cycling) confirms suitability for high-humidity environments — a detail often missed on standard MCB listings.

Frequently asked questions

How do I get current pricing and availability for A9FDB625?

The A9FDB625 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9FDB625's listed depth (72 mm) on this component line?

The A9FDB625 has a depth of 72 mm, with a width of 36 mm and height of 81 mm, fitting the standard Acti9 modular envelope.

What compliance documentation does this brand provide for A9FDB625 (RoHS, REACH, UL, IEC)?

The A9FDB625 is certified to EN/IEC 62606 for arc-fault detection and IEC 60898-1 for MCB performance. It carries a pollution degree 2 rating and overvoltage category III. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request.

MPN